CA12 Multi-Zone Professional PA Amplifier
Introduction
The CA12 is a major step forward in installation amplifier technology. Twelve mono Zone power amplifiers,
featuring 85% class D design technology, can operate as 6 independent Zone amplifiers. Self-explanatory
Input and Output connections are easy to follow since any of the 12 mono amplifiers can be connected to
either 70-Volt, 8-Ohm or 4-ohm speaker circuits.
Each of the 12 mono amplifiers has their own input and output connectors and level controls. Up to 6
stereo Zones (4-ohm or 70-Volt at 50 Watts / channel), 6 mono/bridged Zone amplifiers (110 Watt bridged
8-ohm or 140-Volt). Each Zone can be configured independently allowing a combination of Stereo 4-ohm
or 70 Volt and Mono/Bridged 8-ohm or 140 Volt Zones. Dual-function LEDs on the front panel provide both
activity and Clip indication for each pair of amplifiers, which also have their own button-selectable Limiter;
Stereo/Bridge modes and 4-ohm/70V modes are also selectable.
The Ch. Input Line/Bus switch selects between either the Bus Input (button depressed) or the individual
Zone’s Input signal. Additional features include: any amplifier with no signal at its input is automatically
shut off and the CA12 is able to operate either on 120V/60Hz or 220V/50Hz AC mains.
Features and Functions
AC Mains. The CA12 comes configured to connect to 115V/60Hz mains. For use with 230V/50Hz mains set
the rear panel Voltage Select switch to 230V (also, replace the T10.0AL/250V fuse with a T5.0AL/250V fuse).
Front Panel
1. Left/Mono and Right Controls
These controls regulate the level for each amplifier. For the Zones set up in Mono/Bridge
mode only the Left/Mono Control will affect the level.
2. On/Clip LED
The individual channel’s On/Clip LED will flash to indicate activity, flashing red will indicate
clipping. Reduce levels if clipping is indicated (the LED does not indicate which Zone
channel is clipping).
3. Power
This switch turns the AC mains On or Off.